P0041 – 2008_FORD_FUSION

Code : P0041
Make : 2008_FORD_FUSION
Description : P0041 2008 FORD FUSION Oxygen Sensor Signal Swapped Bank 1 Sensor 2 / Bank 2 Sensor 2
Possible causes :
– Crossed HO2S harness connectors
– Crossed HO2S wiring at the harness connectors
– Crossed HO2S wiring at the PCM connectors
– Bank 1 Sensor 1 / Bank 2 Sensor 1 harness is open or shorted
– Bank 1 Sensor 1 / Bank 2 Sensor 1 circuit connectors (wrong connection
Solutions :
– Carry out a Reset via CarDiag
– Choose a better quality fuel
– Check that the tank cap is securely closed
– Check the oil level and add more if it is lower than MAX
– Restart an Automatic diagnostic via CarDiag
– If the fault persists, you can check the “Possible causes” listed above : visually inspect (by yourself (tutorials to come) or by a professional) the wiring harness and the associated connectors, check for damaged components, and look for broken, bent, pushed, or corroded connector pins.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top