Code :  P1A24
Make :  CADILLAC
Description :  P1A24 CADILLAC Hybrid Battery 1 Voltage
Possible causes : 
   – Faulty Energy Storage Box (ESB) Battery
   – Faulty Battery Energy Control Module (BECM)
   – Battery Energy Control Module (BECM) harness is open or shorted
   – Battery Energy Control Module (BECM) circuit poor electrical connection
Solutions : 
   – Carry out a Reset via CarDiag
   – Choose a better quality fuel
   – Check that the tank cap is securely closed
   – Check the oil level and add more if it is lower than MAX
   – Restart an Automatic diagnostic via CarDiag
   – If the fault persists, you can check the “Possible causes” listed above : visually inspect (by yourself (tutorials to come) or by a professional) the wiring harness and the associated connectors, check for damaged components, and look for broken, bent, pushed, or corroded connector pins.