P015C – FORD

Code : P015C
Make : FORD
Description : P015C FORD Oxygen Sensor Delayed Response Rich to Lean Bank 2 Sensor 1
Possible causes :
– Faulty Heated Oxygen Bank 2 Sensor 1
– Heated Oxygen Bank 2 Sensor 1 harness is open or shorted
– Heated Oxygen Bank 2 Sensor 1 circuit poor electrical connection
– Inappropriate fuel pressure
– Faulty fuel injectors
– Intake air leaks may be faulty
– Exhaust g
Solutions :
– Carry out a Reset via CarDiag
– Choose a better quality fuel
– Check that the tank cap is securely closed
– Check the oil level and add more if it is lower than MAX
– Restart an Automatic diagnostic via CarDiag
– If the fault persists, you can check the “Possible causes” listed above : visually inspect (by yourself (tutorials to come) or by a professional) the wiring harness and the associated connectors, check for damaged components, and look for broken, bent, pushed, or corroded connector pins.

Leave a Comment

Your email address will not be published. Required fields are marked *